Login|Register|Forget password|Dashboard Back to Home|Contact|Shopcart
Unverified1st Year

New Concept Electric Inc.  

Search
新闻中心
  • 暂无新闻
产品分类
  • 暂无分类
联系方式
  • 联系人:Miss Katrina Zhu
  • 电话:86-15921273532
  • 传真:86-514-87849108
站内搜索
 
荣誉资质
  • 暂未上传
友情链接
  • 暂无链接
首页 > Products > High Voltage Spring Operation Mechanism Type Circuit Breaker
High Voltage Spring Operation Mechanism Type Circuit Breaker
单价 面议对比
询价 暂无
浏览 290
发货 Chinajiangsuyangzhou
库存 5000
过期 长期有效
更新 2020-08-18 10:10
 
详细信息
Product Name: High Voltage Spring Operation Mechanism Type Circuit Breaker Model NO.: ZW32 Certification: ISO9001-2000 Function: Overcurrent Protection and Ovp Type: Circuit Breaker Poles Number: Unknown Structure: Spring Strut Type Installation: Fixed Arc-extinguishing Medium: Spring Speed: High-Speed Circuit Breaker Operation: Manual Type Breaking Capacity: High Voltage Circuit Breakers Circuit Breaker Mechanical Life: 10000 Times Second Circuit 1 Min Withstand Voltage: 2kv Altitude: <2000 Working Ambient Temperature: -50-+50 Trademark: New Concept Electric Transport Package: Wood Specification: 80Kg Origin: Yangzhou HS Code: 8535210000 Product Description Company IntroductionNew Concept Electric Inc. was founded in October 2001, with a rigistered capital of 57 million Yuan. The company now covers an area of 77601 square meters (116 acres), and has a plant area of 20000 square meters. It is a national high-tech enterprise that specializes in the research and development, manufacturing, sales and service of intelligent medium & high voltage switchgear. Also the company is a leading manufacturer for solid insulated switchgear in China.Certifications shown below:ZW32-12 Type outdoor AC high voltage vacuum circuit breakers are used in outsidedistribution system withrated voltage of 12kV and three phase AC frequency 50Hz. It is used for open and close overload current and short-circuit current in electric system. It is adaptable for control and protection functions in substation and industrial and mining enterprises, and also countryside electricity system. It can also be used as seperate switch, and by adding controller, achieve automation in distribution system.This product conforms to IEC60044-1, IEC60060, IEC60068-2, IEC60099-4, IEC60255-27, IEC60270, IEC60280.1, IEC60529, IEC60694, IEC60815-1, IEC60870-5-101, IEC61000-4, IEC61243-5, IEC62271,standards, etc.Major Technical Parameters are shown below:Rated voltage12kVRated current630ARated frequency50HzRated short-duration (1 min) power frequency withstand voltage42/48kVRated short-circuit breaking current20kARated short-duration withstand current (4s)20kARated lightning impluse withstand voltage(to earth/break)75/85kVRated short-circuit making current (peak value)50kARated peak withstand current50kARated short-circuit currentbreaking times30TimesMechanical service life of vacuum circuit breaker10000TimesSecond circuit 1 min power frequency withstand voltage2 kVUsing EnvironmentDescriptionUnitUsing Environment ValueSurrounding AirMax TemperatureºC+50Min Temperature-50Max Daily Temperature DifferenceK30Altitudem≤2000Solar Radiation IntensityW/cm20.1Pullution ClassIVIcing-Thicknessmm10HumidityAverage Value of Daily Relative Humidity%≤100Average Value of Monthly Relative Humidity≤95Earthquake Torelance AbilityDegree≤8Test reportsMain Functions:Protective Function - It will indentify fault current automatically; realize instantaneous current cutoff, time limited current break, regular flow, directional flow, overvoltage, under-voltage, single phase ground protection of small current ground system, and cooling load start and inhibition of open circuit, and other functions.Measurement Function - Measure three-phase current, three-phase voltage, active power, reactive power, active energy, reactive energy, peak/valley electricity, power factor and frequency, ect.Controlling Function - It can realize on-site operation and remote control. Meanwhile, achive fault location of circuit, fault isolation automatically, resume power supply for the circuit without fault rapidly by requirement; realize automatic load shedding under low frequency, capacitor automatic cutting, automatic cutting of backup power, and other controlling functions.Communication Function - It can report fault, operation and controlling information to appointed personnel through wireless public network or special communication network; support various kinds of communication ways and agreement; realize setting parameters modification by handhold PDA. The controller releases the instruction of self-inspection from PDA and feedback the self-inspection information to PDA terminal.Data Record Function - Record, save and run operation and fault information automatically.Synchronous Switching On/Off Function - According to the features of load, it searches zero crossing point automatically; adapt itself to the discreteness of switch parameter and impact of environment factors; realize synchronous switching on/off; restrain over voltage of operation and inrush phenomenon effectively, especially suitable for switching capacitor and transformer.Intelligence Function - It can carry out on-line conprehensive analysis of power network parameters, on-line performance parameter measurement of circuit breaker, and on-line programming; cooperate with the main station pf power distribution automatic system; realize the function of remote control management of switch device, and on-site, remote or hierarchical control type power distribution automation system.Invention patents